Polymex P-3017 Prosil Polyurethane Electric Casting Resin

Two-component, solvent-free, polyurethane based electrical insulation and casting resin.

Abrasion resistant, resistant to acid-alkali and other chemical and corrosive substances. It hardens at low temperatures without significant volume change. Drying time can be shortened thanks to catalysts. Absolutely no solvent. Prosil Polyurethane Electric Casting Resin

Areas of Use:

Prosil Polyurethane Electrical Casting Resin Suitable for use in renewable cable joint exemptions, power insulated connections, underground, above ground telephone and energy cables, electronic circuit coating, surface coating, park and garden lighting, water pools, all kinds of humid environments and in water.

In the electrical cable industry: used in the casting of cable headers and joint exemptions, end connections, insulation of underground cable joints. It is a casting resin used in submersible pumps, aquarium filters and in protecting the electrical parts of the motor from water. It prevents vibration in the pump. It is used in sections where insulation is required in the electrical cable industry. Prosil Polyurethane Electric Casting Resin

ColorCream, tile, black, green, black, green and any desired color
BrightnessGlossy or matte
Density ( 20 oC)A=1.4±0.1 B:1.22±0.05
Hardness Shore A45-50
Binding SubstancePolyurethane Resin
% Elongation35
Tensile Strength0.85 Mpa
Volume Self-resistance1,7*1013 Ω cm
Viscosity (25 oC)75 Pas
Electrical Insulationup to 5 Kw
Flash PointPolyol:250 oC
Application Temperature5-35 oC
KurumaInitial drying: 1 hour Final drying: 2 hours
Mode of applicationBulk, roller, trowel, Airless

Prosil Polyurethane Electric Casting Resin Implementation:
The surface to be treated must be dry and clean. It should be cleaned from mineral oil, dirt, rust and burrs. During application, the surface and ambient temperature should be min. 8 oC Max. 30 oC should be ensured. The packaging should not be left under the sun, should be protected from frost and dampness, and no foreign material should be added.

Pour Polymex-3017; Component B into Component A. Mix until a homogeneous mixture is obtained. The place or ground to be used must be cleaned from mineral oil, dirt, rust and burrs. The prepared mixture should be used within 30 to 40 minutes. If not all of the material will be used, the material should be weighed precisely according to the mixture ratio written on the label. Prosil Polyurethane Electric Casting Resin

Safety Precautions:
Skin contact should be avoided; in case of contact, wash with plenty of water and soap. Empty packages cannot be used as food storage containers. Direct inhalation should be avoided, masks, goggles and gloves suitable for chemical inhalation should be used. Prosil Polyurethane Electric Casting Resin

Notes
All technical data contained in this product data sheet are based on laboratory experiments. Actual data may vary due to conditions beyond the control of AŞY POLYMEKS KİMYA SAN TİC LTD ŞTİ. Prosil Polyurethane Electric Casting Resin

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Sorry, no attachment available !
architeck-subscribe-image
Subscribe to Our Mailing List
Be aware of all the campaigns and innovations
en_USEnglish