Polymex P-2021 Fireproof Heat Resistant Epoxy Paint

Two-component, solvent epoxy resin based, 450°C temperature resistant paint. Thanks to the heat resistant pigments it contains, softening and darkening is observed when exposed to 450°C, but it does not catch fire. Epoxy Resin and Siliconized Zinc Phosphate Resin Based, antimony trioxide additive, resistant to combustion thanks to special resin additive. Silicone resin based, aluminum pigment containing top coat Fireproof Heat Resistant Epoxy paint with very high covering power.

Polymex P-2021 Fireproof Heat Resistant Epoxy Paint
Heat Resistant Fireproof Epoxy paint It shows excellent adhesion to concrete and wood surfaces. Does not crack, spill or blister. On all kinds of walls and wooden surfaces in the interior of buildings. Especially on fire escapes, steel structures, hospitals, schools, airports where the risk of fire is high, 2 coats are applied appropriately. When the fire or heat source comes into contact with the surfaces painted with Heat Resistant Fireproof Epoxy paint, the film layer cuts the heat and mass transfer to the main substrate. With the end of the burning materials, the fire ends. It does not carry flame in any way. When a material that burns for 5 minutes during a fire is painted with Polmex-20031, this time finds 2 hours Heat Resistant Fireproof Epoxy paint. FIRE REACTION EXPERIMENT Heat Resistant Fireproof Epoxy Paint: Classification according to TS EN 13501-1:2013 standard as a result of Fire Resistance Tests performed at TSE Istanbul Ex Laboratory: B S1 d0 (with 25 µ thickness application on 1 mm thick sheet metal). Fireproof Heat Resistant Epoxy paint Areas of Use: Heat Resistant Fireproof Epoxy Paint: It is safely applied on surfaces in contact with high temperatures. It is used for painting the surfaces of chimneys, furnaces and motor hair steel buildings. The surfaces to be newly applied must be cleaned very well. Better results are obtained if a thin coat is applied and a second coat is applied on it. 450 oC’ a kadar ısıya mukavemet göstermektedir. Yanmaz Isıya Dayanıklı Epoksi  boyası Pasif sistemlerin aktif sistemlerden farkı herhangi bir tetikleyiciye ihtiyaç duymaksızın çalışmalarıdır. Yangına dayanıklı kapılar, bariyerler ve yapısal çeliğin korunması gibi.  Pasif sistemlerin çalışması yangın sırasında kendiliğindendir. Örneğin, yapısal çeliği koruyan bir boya yangın sırasında şişerek çelik üzerinde bir yalıtım tabakası oluşturur ve bu tabaka ısının çeliğe ulaşmasını geciktirir. Isıya Dayanıklı Yağlı Boyası  What is Fire Retardant Paint? Isıya Dayanıklı Yanmaz Epoksi  boyası Yangın geciktirici boyalar görünüm olarak normal boyalara benzerler. Ortam sıcaklığında stabildirler. Ancak yangın sırasında bir dizi kimyasal reaksiyon sonucu uygulanma kalınlıklarının 3 – 4 katı kadar şişerek çelik üzerinde bir yalıtım tabakası oluştururlar. Isıya Dayanıklı Yağlı Boyası boşluklu ve dolu gövdeli kolonlarda 30 dakikaya kadar EN-13381’e göre test edilmiş ve başarılı olmuştur. Çelik eleman üzerine uygulanacak boya kalınlığı yapılan testlerden alınan veriler ışığında şu değerlerin bilinmesi ile hesaplanabilir: Yangın Geciktirme Süresi (30 dak.- 180 dak.) Isıya Dayanıklı Yağlı Boyası Yangın geciktirici boyanın amacı ısının çeliğe geçmesini engellemek olduğu için, yangın sırasında boyanın bozulması ile meydana gelen yalıtım tabakasının da çelik yüzeyden ayrılmaması önemlidir. Çelik yüzeyine tutunmayan boya yalıtım görevini yapamayacaktır. Ayrıca boyanın sıcaklık sırasında baş etmesi gereken en büyük problemlerden biri de çelik üzerinde, sıcaklıkla meydana gelen deplasmanları tolere edebilmesidir. Astar yangın geciktirici boyanın çelik yüzeyle arasındaki tabakadır. Astar artan sıcaklıklarla beraber yüzeyden ayrılırsa, üzerindeki yangın geciktirici boya da ayrılacak ve boya görev yapmayacaktır. Bu yüzden mutlaka üretici firma onayı olan astarları kullanılmalıdır.   Son kat yağlı boya ise yangın geciktirici boyayı dış etkenlerden korumak için gereklidir. Ayrıca dekoratif renk de son kat boya ile verilebilir.   yangın geciktirici yağlı boya, 450 oC limit sıcaklığa göre değerlendirildiğinde EN 13381’e göre 1 saat yangını geciktirebilmektedir. 450 oC limit sıcaklığa göre değerlendirildiğinde EN 13381’e göre 1 ½ saat yangını geciktirebilmektedir. 1 ½ saat çelik üzerinde boya kalabilmektedir. Boya bu özellikleri ile Dünya’daki en gelişmiş ürünler arasında yer almaktadır. Yanmaz Isıya Dayanıklı Epoksi  boyası. What do fire retardant paints do? It produces fire retardant paints for the protection of structural steel. During a fire, the ambient temperature can rise from 20oC to 1000oC in a few minutes. The increase in temperature causes the temperature of the steel, which is the carrier of the structure, to increase. Steel loses its strength at high temperatures. At 600.oC, steel loses half of its carrying power. After 855.oC, buckling starts in the bearing steel. After this point, the structure faces sudden collapse. The current fire regulations in Turkey require protection with materials tested according to TSE or EN standards so as not to exceed 600.oC on the carrier steel. It is not used at these degrees.
Tipi     TS EN 13501-1 Nisan 2013 Çizelge 1 B S1 d0 Sınıfı kriterlerine uygundur. Renk  :  RAL renkleri Görünüm   : Yarı Parlak İnceltici  : Epoksi Tiner Ağırlıkça Katı Madde,:  %   65 Yoğunluk   : 1,50 g/cm³ Sarfiyat  :  Sarfiyat tablosuna bakınız. Ambalajı  :16 kg A Bileşeni + 4 kg B bileşeni:Toplam 20 kg Alevlenme :Noktası >85 °C Karışım Oranı: 4 / 1 Uygulama Yöntemleri :  Fırça, Rulo, Havalı Tabanca, Havasız Tabanca Karışım Ömrü  İ 1 saat / 25°C Raf Ömrü :  1 yıl Katlar Arası Bekleme Süresi :  6 saat/25 °C Kuruma Süresi :  12 saat/25 °C Mekanik Mukavemet : 7 gün Ekipman Temizliği : Epoksi Tiner
Heat Resistant Oil Paint application surfaces should be completely cleaned from moisture, dirt, rust and old paint residues and sanded. It is ready for use and should be applied in layers. There should be at least 2 hours between coats. The temperature of the application surfaces should be +5 oIt should be above C. Application should be by spraying Airlas or Roller. The application should be started at least 2 hours after the primer coat is applied. Herkat application is 20-25 micron thickness, the application should be applied as 1 coat primer 2 coats Heat Resistant Fireproof Epoxy paint. Why Do We Need Fire Retardants? Heat Resistant Fireproof Epoxy paint The purposes of all fire retardant systems and materials are primarily to prevent the spread of fire and smoke and to ensure that the people inside the building can safely exit the building, and then to prevent the spread of fire to neighboring structures while maintaining the integrity of the structure. Heat Resistant Fireproof Epoxy paint Occupational Health and Safety Recommendations İşçi Sağlığı ve İş Güvenliği Talimatlarında belirtilen iş elbiseleri, koruyucu eldiven/gözlük/maske benzeri tüm iş güvenliği ekipmanlarının uygulama esnasında kullanılması zorunludur. Çalışma sahasının havalandırılması gereklidir. Depo ve stok alanlarına ateş ile yaklaşılmamalıdır. Ürünün deri ve göz ile teması kesinlikle önlenmeli, böyle bir durumda hemen bol su ile ürünün temas ettiği yer yıkanmalı ve zaman geçirmeden tıbbi yardım alınmalıdır. Yiyecek ve içeceklerin de ürün ile temas etmemesi gereklidir.  Çocuklardan uzak yerlerde depolanmalı ve korunmalıdır. Daha fazla bilgi için Malzeme Güvenlik Bilgi Formu (MSDS) incelenmelidir. Yanmaz Isıya Dayanıklı Epoksi  boyası. Ayrıca ürünün uygulanması, yeterli teknik bilgiye, donanım ve deneyime sahip kişilerce yapılmalıdır. Bu konudaki sorumluluk münhasıran kullanıcıya aittir. Polymex- Isıya Dayanıklı Yanmaz Epoksi  boyası
SAFETY WARNINGS S2: Çocuklardan uzak tutunuz. S3/7/9: Ambalajında kapalı olarak serin ve iyi havalandırılmış yerde muhafaza ediniz. S24/25: Göz ve deriye temastan kaçının. S46: Yutma ve içme halinde derhal doktora başvurun. S51: İyi havalandırılmış alanlarda çalışın. DANGER WARNINGS R10: Flammable. Responsibility POLYMEX KİMYA San. And Tic. is responsible for the technical information given in this data sheet and the quality of the product. Apart from this, it is responsible for any direct or indirect consequences that may arise from the use of the product. POLYMEX KİMYA San. And Tic. cannot be held responsible. This technical document is valid until a new one is issued and supersedes all previous editions. (10/2023) Polymex - Heat Resistant Fireproof Epoxy Paint   Polymex Kimya San. ve Tic. may make changes in the nature of the product. Changes in this regard POLYMEX KİMYA San. and Tic. will be notified by the user. Fireproof Heat Resistant Epoxy paint. The product is a flammable material and safety precautions must be taken during product use. These precautions are not limited to those listed above as examples, it is the sole responsibility of the user to take all safety precautions. Polymex- Heat Resistant Fireproof Epoxy Paint

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

architeck-subscribe-image
Subscribe to Our Mailing List
Be aware of all the campaigns and innovations
en_USEnglish