APPLICATION AREAS
It is used on ship decks, helipads, ramps, offshore platforms wherever there is a need for durable, non-slip deck coating. Helipad Decking
APPLICATION
Surface Preparation
The application surface must be clean, dry and free from dirt. Oil and grease on the metal surface should be removed with detergent or steam, salt and other contaminants should be removed with high pressure fresh water. After cleaning, the surface should be blasted at Sa 2½ level according to ISO 8501-1 standard for optimum results. After surface preparation, the surface should be primed with Polymex-999-. It is designed as a primer for Polymex-7011-. P-7013-Helipad Flooring
Application Conditions / Limits
Surface Temperature: Minimum +10°C / Maximum +39°C
Environmental Temperature: Minimum +10°C / Maximum +45°C
Surface Moisture Content: Moisture content by weight < 4%Relative Humidity Up to 85%Dew Point: Surface ground temperature should be at least 3°C above the condensation point.Preparation of the mixture
Component A is mixed until it is homogeneous, then all of the hardener in the small box is poured into the main material and mixed until a homogeneous mixture is obtained. After letting the mixture rest for 1-2 minutes, pour enough amount onto the prepared surface and apply with a special roller.
The recommended amount of product should be used for the desired surface pattern (plowed field appearance). The desired pattern cannot be obtained in thick or thin applications.
The distance between parallel rows of peaks in the desired surface pattern should be between 12.7-25 mm. Profile peak height should be between 1.6-2.3 mm. Polymex-7013-Helipad Flooring
Application tools:
Special roll
Thinner NO THINNER!
Cleaning Equipment used with Polymex Thinner should be cleaned before the paint dries.